Frequently Asked Questions

We have summarized the questions that you often inquire about.Please refer to it before you inquire.
See “Trouble Shooting” for information on problems.

Detailed Search

Rating Questions

Tell me how to use the rating. For example, a product called Eco Ball Z, which can be used up to 4.12 MPa up to 38°C and up to 0.98 MPa up to 150°C, can be used up to what MPa when used at 100°C?

It can be calculated by the proportional interpolation method.
0.98 + (4.12 – 0.98) x (150-100) / (150 – 38) = About 2.38 MPa

The calculation method is described in the catalog, so please refer to it.
In addition, an automatic calculation formula can also be used from our website.

Please check the rating of each product in the catalog before using it.

Go to download catalogs and instruction manuals
Go to Various Calculation Tools

Up to what pressure can the model 400 valve be used?

“Model 400” indicates the pressure unit, PSI, in the United States and the valve can be used up to a maximum operating pressure of 2.75 MPa at room temperature (38°C or less).

Up to what pressure can the model 600 valve be used?

“Model 600” indicates the pressure unit, PSI, in the United States and the valve can be used up to a maximum operating pressure of 4.12 MPa at room temperature (38°C or less).

Up to what pressure can the model 800 valve be used?

“Model 800” indicates the pressure unit, PSI, in the United States and the valve can be used up to a maximum operating pressure of 5.49 MPa at room temperature (38°C or less).

Up to what pressure can the model 1000 valve be used?

“Model 1000” indicates the pressure unit, PSI, in the United States and the valve can be used up to a maximum operating pressure of 6.86 MPa at room temperature (38°C or less).

Contact us

For inquiries about product technology, product purchases,
catalogs, and quality